Product Description

GHC Oldham type coupling cross sliding clamp coupling


Description of
 GHC Oldham type coupling cross sliding clamp coupling
>The colloid material is imported PA66, which has good wear resistance, corrosion resistance and electrical insulation
>Sliding design can compensate radial and angular deviation more effectively
>Detachable design, easy to install
>Fastening method of clamping screw

Dimensions of GHC Oldham type coupling cross sliding clamp coupling

model parameter common bore diameter d1,d2 ΦD L LF LP F M tightening screw torque
(N.M)
GHC-16X21 4,5,6,6.35 16 21 8.6 11.6 2.5 M2.5 1
GHC-16X30 4,5,6,6.35 16 30 13.1 11.6 3 M2.5 1
GHC-20X22 5,6,6.35,7,8 20 22 8.6 12.7 2.5 M2.5 1
GHC-20×33 5,6,6.35,7,8 20 33 14.1 12.7 3 M2.5 1
GHC-25×28 5,6,6.35,8,9,9.525,10,11,12 25 28 11.7 16.65 3 M3 1.5
GHC-25X39 5,6,6.35,8,9,9.525,10,11,12 25 39 17.2 16.65 4.2 M3 1.5
GHC-32X33 5,6,8,9,9.525,10,11,12.12.7,14,15,16 32 33 14 19.5 3 M4 2.5
GHC-32X45 5,6,8,9,9.525,10,11,12,12.7,14,15,16 32 45 20 19.5 4.5 M4 2.5
GHC-40X50 8,9,9.525,10,11,12,14,15,16,17,18,19 40 50 23 18.4 7 M5 7
GHC-45X46 8,9,9.525,10,11,12,14,15,16,17,18,19,20,22 45 46 21 18.4 7 M5 7
GHC-50X53 10,11,12.7,14,15,16,17,18,19,20,22,24 50 53 24 15 7.5 M6 12
GHC-50X58 10,11,12.7,14,15,16,17,18,19,20,22,24 50 58 26.5 17.5 8 M6 12
GHC-55X57 10,11,12.7,14,15,16,17,18,19,20,22,24,25,28,30,32 55 57 26 17.5 7.8 M6 12
GHC-63X71 14,15,16,17,18,19,20,22,24,25,28,30,32 63 71 33 24 10 M8 20
GHC-70X77 14,15,16,17,18,19,20,22,24,25,28,30,32,35,38 70 77 29.5 25 12 M8 20

  

model parameter Rated torque
(N.M)*
allowable eccentricity
(mm)*
allowable deflection angle
(°)*
allowable axial deviation
(mm)*
maximum speed
rpm
static torsional stiffness
(N.M/rad)
moment of inertia
(Kg.M2)
Material of shaft sleeve Material of shrapnel surface treatment weight
(g)
GHC-16X21 0.7 0.8 3 ±0.2 8500 30 5.5×10-7 High strength aluminum alloy P A 6 6 Anodizing treatment 8
GHC-16X30 0.7 0.8 3 ±0.2 9000 30 5.9×10-7 12
GHC-20X22 1.2 1.2 3 ±0.2 6500 58 1.3×10-6 13
GHC-20×33 1.2 1.2 3 ±0.2 7000 58 1.5×10-6 19
GHC-25X28 2 1.6 3 ±0.2 5500 130 4.0×10-6 24
GHC-25X39 22 1.6 3 ±0.2 6000 130 4.5×10-6 35
GHC-32X33 4.5 2 3 ±0.2 4500 270 1.3×10-5 48
GHC-32X45 4.5 2 3 ±0.2 4800 270 1.5×10-5 67
GHC-40X50 9 2.4 3 ±0.2 3600 520 4.2×10-5 114
GHC-45X46 12 2.5 3 ±0.2 3500 800 4.5×10-5 140
GHC-50X53 19 2.6 3 ±0.2 3000 800 1.0×10-4 190
GHC-50X58 19 3 3 ±0.2 3000 800 1.1×10-4 215
GHC-55X57 25 3.2 3 ±0.2 3000 900 1.3×10-5 260
GHC-63X71 33 3 3 ±0.2 2550 1200 3.5×10-4 455
GHC-70X77 56 3.5 3 ±0.2 2500 1260 4.1×10-5 520

 

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

oldham coupling

What are the Potential Limitations or Drawbacks of Using an Oldham Coupling?

While Oldham couplings offer numerous advantages, they also have some limitations and drawbacks that should be considered when selecting a coupling for a specific application:

1. Limited Misalignment Capacity: Oldham couplings can only accommodate small amounts of angular and axial misalignment between the shafts. They are not suitable for applications with high levels of misalignment as excessive misalignment can lead to premature wear and failure of the center disc.

2. Speed Limitations: Oldham couplings are generally not recommended for high-speed applications. The flexible center disc has a maximum speed limit, and exceeding this limit can cause the disc to fatigue and fail over time.

3. Temperature Sensitivity: The performance of Oldham couplings can be affected by temperature fluctuations. Extreme temperatures can impact the flexibility and integrity of the center disc material, leading to reduced coupling performance.

4. Backlash in High-Precision Systems: While Oldham couplings minimize backlash compared to some other couplings, they may still have some inherent clearance between the hubs and the center disc, leading to a slight amount of backlash. In ultra-high-precision systems, this slight backlash may be a concern.

5. Material Compatibility: The material used for the center disc must be chosen carefully to ensure compatibility with the specific application’s environment and the media being conveyed. Some aggressive chemicals or harsh environments may degrade the material over time.

6. Maintenance: Oldham couplings require periodic inspection and maintenance to ensure proper functioning. The center disc may wear out over time and need replacement, especially in applications with high torque or frequent start-stop cycles.

Despite these limitations, Oldham couplings remain a popular choice in many applications due to their vibration reduction, backlash minimization, and moderate misalignment compensation capabilities. However, it is essential to carefully assess the specific requirements of the application and consider the potential drawbacks before selecting an Oldham coupling.

oldham coupling

What are the Maintenance Requirements for Oldham Couplings to Ensure Their Longevity?

Maintaining Oldham couplings is essential to ensure their longevity and optimal performance. Proper maintenance practices can prevent premature wear and damage, reducing the risk of unexpected failures and downtime. Here are some maintenance requirements to consider for Oldham couplings:

  • Regular Inspection: Perform regular visual inspections of the coupling to check for signs of wear, misalignment, or damage. Look for cracks, corrosion, or any unusual behavior during operation.
  • Lubrication: Oldham couplings may require periodic lubrication to reduce friction between moving parts and prevent excessive wear. Check the manufacturer’s guidelines for the appropriate lubrication schedule and type of lubricant to use.
  • Alignment: Proper alignment is crucial for Oldham couplings to function correctly. Ensure that the shafts and hubs are correctly aligned to avoid additional stress on the coupling components.
  • Torque Check: Periodically check the coupling’s torque to verify that it is within the recommended operating range. Over-torqueing or under-torqueing can lead to coupling failure.
  • Environmental Protection: In harsh environments or applications exposed to contaminants, consider using protective covers or enclosures to shield the coupling from debris, dirt, and moisture.
  • Replacement of Worn Parts: If any component of the Oldham coupling shows signs of wear or damage, promptly replace it with a new one from the manufacturer.
  • Proper Handling: During installation or maintenance, handle the coupling components with care to avoid any accidental damage.

It is crucial to follow the manufacturer’s maintenance guidelines and recommendations specific to the Oldham coupling model being used. Proper maintenance practices will not only extend the coupling’s lifespan but also contribute to the overall reliability and efficiency of the mechanical system it is part of.

oldham coupling

Advantages of Using an Oldham Coupling Compared to Other Types of Couplings

An Oldham coupling offers several advantages over other types of couplings, making it a preferred choice in certain applications:

  • Misalignment Compensation: The Oldham coupling can handle both angular and axial misalignments between shafts. It allows for up to a few degrees of misalignment while transmitting torque smoothly, reducing the risk of premature wear and failure caused by misalignment.
  • No Backlash: Unlike some other flexible couplings, the Oldham coupling has minimal backlash. This means there is little to no play or clearance between the coupling components during rotation, ensuring precise torque transmission and positioning in high-precision applications.
  • Vibration and Noise Damping: The sliding action of the middle block in the coupling helps to isolate the shafts from each other, reducing vibrations and noise during operation. This feature is beneficial in applications where vibration dampening is critical to equipment performance and longevity.
  • High Torque Transmission: Oldham couplings can handle relatively high torque transmission, making them suitable for applications with moderate to high torque requirements.
  • Low Maintenance: Due to its design, the Oldham coupling experiences minimal wear during operation, leading to lower maintenance requirements and longer service life.
  • Easy Installation: Oldham couplings are relatively easy to install and remove, simplifying maintenance and replacement procedures.
  • Electrically Insulating: Some Oldham couplings are available with non-conductive materials, providing electrical isolation between shafts, which is essential in certain applications.
  • Cost-Effective: Compared to other high-performance couplings, Oldham couplings are often more cost-effective, providing reliable performance without breaking the budget.

Overall, the Oldham coupling is an excellent choice in applications where misalignment compensation, precision torque transmission, vibration dampening, and low maintenance are critical factors for successful operation. Its unique design and features make it suitable for various industrial and automation systems, contributing to smoother and more efficient mechanical power transmission.