China Best Sales Oldham Type Coupling Rigid Coupling Ghc-32X33 oldham coupling

Product Description

GHC Oldham type coupling cross sliding clamp coupling


Description of
  GHC Oldham type coupling cross sliding clamp coupling
>The colloid material is imported PA66, which has good wear resistance, corrosion resistance and electrical insulation
>Sliding design can compensate radial and angular deviation more effectively
>Detachable design, easy to install
>Fastening method of clamping screw

Dimensions of  GHC Oldham type coupling cross sliding clamp coupling

model parameter common bore diameter d1,d2 ΦD L LF LP F M tightening screw torque
(N.M)
GHC-16X21 4,5,6,6.35 16 21 8.6 11.6 2.5 M2.5 1
GHC-16X30 4,5,6,6.35 16 30 13.1 11.6 3 M2.5 1
GHC-20X22 5,6,6.35,7,8 20 22 8.6 12.7 2.5 M2.5 1
GHC-20×33 5,6,6.35,7,8 20 33 14.1 12.7 3 M2.5 1
GHC-25×28 5,6,6.35,8,9,9.525,10,11,12 25 28 11.7 16.65 3 M3 1.5
GHC-25X39 5,6,6.35,8,9,9.525,10,11,12 25 39 17.2 16.65 4.2 M3 1.5
GHC-32X33 5,6,8,9,9.525,10,11,12.12.7,14,15,16 32 33 14 19.5 3 M4 2.5
GHC-32X45 5,6,8,9,9.525,10,11,12,12.7,14,15,16 32 45 20 19.5 4.5 M4 2.5
GHC-40X50 8,9,9.525,10,11,12,14,15,16,17,18,19 40 50 23 18.4 7 M5 7
GHC-45X46 8,9,9.525,10,11,12,14,15,16,17,18,19,20,22 45 46 21 18.4 7 M5 7
GHC-50X53 10,11,12.7,14,15,16,17,18,19,20,22,24 50 53 24 15 7.5 M6 12
GHC-50X58 10,11,12.7,14,15,16,17,18,19,20,22,24 50 58 26.5 17.5 8 M6 12
GHC-55X57 10,11,12.7,14,15,16,17,18,19,20,22,24,25,28,30,32 55 57 26 17.5 7.8 M6 12
GHC-63X71 14,15,16,17,18,19,20,22,24,25,28,30,32 63 71 33 24 10 M8 20
GHC-70X77 14,15,16,17,18,19,20,22,24,25,28,30,32,35,38 70 77 29.5 25 12 M8 20

  

model parameter Rated torque
(N.M)*
allowable eccentricity
(mm)*
allowable deflection angle
(°)*
allowable axial deviation
(mm)*
maximum speed
rpm
static torsional stiffness
(N.M/rad)
moment of inertia
(Kg.M2)
Material of shaft sleeve Material of shrapnel surface treatment weight
(g)
GHC-16X21 0.7 0.8 3 ±0.2 8500 30 5.5×10-7 High strength aluminum alloy P A 6 6 Anodizing treatment 8
GHC-16X30 0.7 0.8 3 ±0.2 9000 30 5.9×10-7 12
GHC-20X22 1.2 1.2 3 ±0.2 6500 58 1.3×10-6 13
GHC-20×33 1.2 1.2 3 ±0.2 7000 58 1.5×10-6 19
GHC-25X28 2 1.6 3 ±0.2 5500 130 4.0×10-6 24
GHC-25X39 22 1.6 3 ±0.2 6000 130 4.5×10-6 35
GHC-32X33 4.5 2 3 ±0.2 4500 270 1.3×10-5 48
GHC-32X45 4.5 2 3 ±0.2 4800 270 1.5×10-5 67
GHC-40X50 9 2.4 3 ±0.2 3600 520 4.2×10-5 114
GHC-45X46 12 2.5 3 ±0.2 3500 800 4.5×10-5 140
GHC-50X53 19 2.6 3 ±0.2 3000 800 1.0×10-4 190
GHC-50X58 19 3 3 ±0.2 3000 800 1.1×10-4 215
GHC-55X57 25 3.2 3 ±0.2 3000 900 1.3×10-5 260
GHC-63X71 33 3 3 ±0.2 2550 1200 3.5×10-4 455
GHC-70X77 56 3.5 3 ±0.2 2500 1260 4.1×10-5 520

 

/* March 10, 2571 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

oldham coupling

Specific Safety Considerations for Using Oldham Couplings in High-Speed Applications

When using Oldham couplings in high-speed applications, there are several safety considerations to keep in mind to ensure the safe and efficient operation of the machinery:

1. Material Selection: Choose high-quality materials for the Oldham coupling components to withstand the stresses and forces experienced at high speeds.

2. Proper Installation: Ensure the coupling is installed correctly and securely to prevent any chances of coupling failure or disengagement during high-speed operation.

3. Balancing: Balance the coupling components accurately to minimize vibration and prevent excessive wear, which can be more pronounced at high speeds.

4. Regular Inspections: Implement a regular inspection and maintenance schedule to identify any signs of wear, misalignment, or damage that may occur due to high-speed operation.

5. Lubrication: Use appropriate lubrication to reduce friction and heat generation, which is crucial in high-speed applications.

6. Temperature Consideration: Monitor the temperature of the coupling during operation as high speeds can result in increased heat generation.

7. Avoid Overloading: Do not exceed the recommended torque and speed limits specified by the manufacturer to avoid overloading the coupling.

8. Coupling Guards: Consider using coupling guards or covers to protect personnel from rotating or moving coupling components in high-speed systems.

9. Emergency Shutdown: Install an emergency shutdown system to quickly stop the machinery in case of coupling failure or other emergencies.

10. Compliance with Standards: Ensure that the Oldham coupling and its installation comply with industry standards and regulations for high-speed applications.

By adhering to these safety considerations and implementing preventive measures, the risk of accidents, machinery damage, and downtime in high-speed applications can be significantly reduced. Always consult the coupling manufacturer’s guidelines and follow best practices for safe operation and maintenance.

oldham coupling

What are the Maintenance Requirements for Oldham Couplings to Ensure Their Longevity?

Maintaining Oldham couplings is essential to ensure their longevity and optimal performance. Proper maintenance practices can prevent premature wear and damage, reducing the risk of unexpected failures and downtime. Here are some maintenance requirements to consider for Oldham couplings:

  • Regular Inspection: Perform regular visual inspections of the coupling to check for signs of wear, misalignment, or damage. Look for cracks, corrosion, or any unusual behavior during operation.
  • Lubrication: Oldham couplings may require periodic lubrication to reduce friction between moving parts and prevent excessive wear. Check the manufacturer’s guidelines for the appropriate lubrication schedule and type of lubricant to use.
  • Alignment: Proper alignment is crucial for Oldham couplings to function correctly. Ensure that the shafts and hubs are correctly aligned to avoid additional stress on the coupling components.
  • Torque Check: Periodically check the coupling’s torque to verify that it is within the recommended operating range. Over-torqueing or under-torqueing can lead to coupling failure.
  • Environmental Protection: In harsh environments or applications exposed to contaminants, consider using protective covers or enclosures to shield the coupling from debris, dirt, and moisture.
  • Replacement of Worn Parts: If any component of the Oldham coupling shows signs of wear or damage, promptly replace it with a new one from the manufacturer.
  • Proper Handling: During installation or maintenance, handle the coupling components with care to avoid any accidental damage.

It is crucial to follow the manufacturer’s maintenance guidelines and recommendations specific to the Oldham coupling model being used. Proper maintenance practices will not only extend the coupling’s lifespan but also contribute to the overall reliability and efficiency of the mechanical system it is part of.

oldham coupling

Installation and Maintenance of Oldham Couplings

Proper installation and maintenance are crucial for ensuring the optimal performance and longevity of an Oldham coupling. Here are the steps to install and maintain an Oldham coupling:

Installation:

  • 1. Inspect the Components: Before installation, carefully inspect the Oldham coupling’s hubs and center disc for any signs of damage or wear.
  • 2. Shaft Preparation: Ensure that the shafts are clean and free from any debris or burrs. Make sure the shaft diameters match the hub bores and keyway dimensions.
  • 3. Center Disc Alignment: Align the center disc with the two hubs so that the slots or keyways on the center disc fit into the corresponding slots on the hubs.
  • 4. Secure the Hubs: Slide the hubs onto the shafts and fasten them securely using appropriate fasteners such as screws or clamps.
  • 5. Tighten Fasteners: Carefully tighten the fasteners according to the manufacturer’s recommendations. Be cautious not to over-torque, as it may lead to distortion or damage to the components.
  • 6. Check Misalignment: Verify that the Oldham coupling can accommodate the required misalignment between the shafts without binding or excessive stress.

Maintenance:

  • 1. Regular Inspection: Periodically inspect the Oldham coupling for signs of wear, damage, or misalignment. Look for any unusual noises or vibrations during operation.
  • 2. Lubrication: Some Oldham couplings may require periodic lubrication for smooth operation. Check the manufacturer’s guidelines for the proper type and amount of lubricant.
  • 3. Replace Worn Components: If any part of the Oldham coupling shows significant wear or damage, replace it with a new component from the original equipment manufacturer (OEM).
  • 4. Alignment Check: Regularly check the alignment of the shafts and the coupling to ensure that the misalignment is within the specified limits.
  • 5. Environmental Considerations: Take into account the operating environment, such as temperature and humidity, and use appropriate materials and coatings to resist corrosion and wear.
  • 6. Follow Manufacturer Guidelines: Always adhere to the manufacturer’s installation, operation, and maintenance instructions to ensure safe and efficient coupling performance.

By following these installation and maintenance practices, an Oldham coupling can provide reliable torque transmission, compensate for misalignment, and contribute to the smooth operation of the connected machinery or equipment.